LINERGY

SPY SYSTEM COMPARISON


SSCENT-00
SSCENT-PR SSPRO-00 SSPRO-PR SSPRO-II SSMINIPLUS SSMINIPLUS SSMINIPLUS SSMINI SSMINI SSMINI SSMICRO

SSCENT-00

SSCENT-PR

SSPRO-00

SSPRO-PR

SSPRO-II

SSMINIPLUS

SSMINIPLUS-00

SSMINIPLUS-170

SSMINI

SSMINI-00

SSMINI-170

SSMICRO
SS1101 SS1102 SS1201 SS1203 SS1202 SS1301 SS1302 SS1303 SS1401 SS1402 SS1403 SS1501
 Power supply 230Vac
50-60Hz
230Vac
50-60Hz

230Vac
50-60Hz

230Vac
50-60Hz

230Vac
50-60Hz
230Vac
50-60Hz
230Vac
50-60Hz

230Vac
50-60Hz

230Vac
50-60Hz

230Vac
50-60Hz

230Vac
50-60Hz

230Vac
50-60Hz

 Display Yes Yes Yes
Yes
No
Yes Yes
Yes No No No No
 Local user interface 7" colour
graphic display with
touch screen

7" colour
graphic display with
touch screen
7" colour
graphic display with
touch screen
7" colour
graphic display with
touch screen

4,3" colour
graphic display with
touch screen
4,3" colour
graphic display with
touch screen
4,3" colour
graphic display with
touch screen

     
 Remote user interface Web server Web server
Web server
Web server
Web server
Web server
Web server
Web server
Web server
Web server
Web server
iOS e Android app
 Printer No Yes No Yes No Optional Optional
Optional
Optional
Optional
Optional
No
 Wireless option Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes
 Max luminaires handled 1280 1280
1280
1280
1280
98 128 170 98 128 170 30
 Number of luminaires on the bus 256 on the central unit
+
128 for each Repeater channel

256 on the central unit
+
128 for each Repeater channel
256 on the central unit
+
128 for each Repeater channel
256 on the central unit
+
128 for each Repeater channel
256 on the central unit
+
128 for each Repeater channel
98 on the central unit
or
98 with Repeater

128 on the central unit
or
128 with Repeater
170 on the central unit
or
170 with Repeater
98 on the central unit
or
98 with Repeater
128 on the central unit
or
128 with Repeater
170 on the central unit
or
170 with Repeater
30 on the central unit
 Max number of groups 32 32 32 32 32 4 4 4 4 4 4 1

 Max number of repeaters

8 8
8
8 8
8 8
8 8 8 8
 Battery Li-ion Li-ion
Li-ion
Li-ion
Li-FePO4
Li-FePO4 Li-FePO4
Li-FePO4
Li-FePO4
Li-FePO4
Li-FePO4
Li-FePO4
 Duration in battery mode 4h 4h
4h
4h
4h
4h
4h
4h
4h
4h
4h
5h
 Data bus characteristics 2 wires with polarity
(twisted and shielded)

2 wires with polarity
(twisted and shielded)
2 wires with polarity
(twisted and shielded)
2 wires with polarity
(twisted and shielded)
2 wires with polarity
(twisted and shielded)
2 wires with polarity
(twisted and shielded)
2 wires with polarity
(twisted and shielded)
2 wires with polarity
(twisted and shielded)
2 wires with polarity
(twisted and shielded)
2 wires with polarity
(twisted and shielded)
2 wires with polarity
(twisted and shielded)
2 wires with polarity
(twisted and shielded)
 Communication protocol TCP/IP via ethernet  TCP/IP via ethernet TCP/IP via ethernet
TCP/IP via ethernet
TCP/IP via ethernet
TCP/IP via ethernet
TCP/IP via ethernet
TCP/IP via ethernet
TCP/IP via ethernet
TCP/IP via ethernet
TCP/IP via ethernet
TCP/IP via Wi-Fi
 Data ports 3 USB
+
1 RJ 45
 3 USB
+
1 RJ 45
3 USB
+
1 RJ 45
3 USB
+
1 RJ 45
1 RJ 45
+
1 clean contact
for error alarm

 1 RJ 45 1 RJ 45
1 RJ 45
1 RJ 45
+
1 clean contact
for error alarm
1 RJ 45
+
1 clean contact
for error alarm
1 RJ 45
+
1 clean contact
for error alarm

 Installation Wall mounted Wall mounted
Rack 19"
(4 U)
Rack 19"
(4 U)
Rack 19"
(1 U)
DIN guide DIN guide DIN guide
DIN guide
DIN guide
DIN guide
DIN guide

 

Back to Spy System >